{"id":7166,"date":"2024-04-29T16:47:59","date_gmt":"2024-04-29T16:47:59","guid":{"rendered":"https:\/\/www.tina.com\/blog\/?p=7166"},"modified":"2025-06-20T04:29:29","modified_gmt":"2025-06-20T04:29:29","slug":"online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit","status":"publish","type":"post","link":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/","title":{"rendered":"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;list=PLScrHAmLYSQAcKY55w-gvpUvBNL4wgQCJ&amp;index=1\">In this video<\/a> we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Startup Transient Simulation<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The startup transient of a DC-DC converter is the period of time during which the converter is transitioning from its off state to its steady-state operating condition.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Startup-Transient-circuit-diagram-1024x310.png\" alt=\"\" class=\"wp-image-7170\" width=\"768\" height=\"233\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Startup-Transient-circuit-diagram-1024x310.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Startup-Transient-circuit-diagram-300x91.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Startup-Transient-circuit-diagram-768x233.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Startup-Transient-circuit-diagram-1200x363.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Startup-Transient-circuit-diagram.png 1258w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> <br>Startup Transient Simulation circuit and diagram<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Redesigning the circuit <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Let&#8217;s redesign the circuit to generate a 3.3 V output voltage.  <br>The Design Tool changed the RTOP resistance to 26.7k and displayed a quick diagram of all the relevant analysis results, based on analytic calculations<em>.<\/em> <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-and-startup-transient_Redesigning-the-circuit-1024x371.png\" alt=\"\" class=\"wp-image-7174\" width=\"768\" height=\"278\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-and-startup-transient_Redesigning-the-circuit-1024x371.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-and-startup-transient_Redesigning-the-circuit-300x109.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-and-startup-transient_Redesigning-the-circuit-768x278.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-and-startup-transient_Redesigning-the-circuit.png 1055w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>The Design Tool changed the RTOP resistance to 26.7k and displayed a quick diagram of all the relevant analysis results, based on analytic calculations.  <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Steady State Analysis<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Steady state analysis of a DC-DC power supply is the analysis of the circuit&#8217;s behavior when it has reached a steady state. This means that the output voltage is constant, except for the ripple voltage, and all the components in the circuit are operating in their steady state conditions.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Steady-state-1024x439.png\" alt=\"\" class=\"wp-image-7182\" width=\"768\" height=\"329\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Steady-state-1024x439.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Steady-state-300x129.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Steady-state-768x329.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Steady-state.png 1062w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>Ripple voltages and current of the outputs <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Line Step Analysis<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Line stepping analysis of DC-DC converters is used to determine how a DC-DC converter responds to changes in the input voltage.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Line-step-circuit-and-diagram-1024x336.png\" alt=\"\" class=\"wp-image-7187\" width=\"768\" height=\"252\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Line-step-circuit-and-diagram-1024x336.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Line-step-circuit-and-diagram-300x99.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Line-step-circuit-and-diagram-768x252.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Line-step-circuit-and-diagram-1200x394.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Line-step-circuit-and-diagram.png 1233w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption><br>Line Step Analysis<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Load Step Analysis<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Load step analysis of DC-DC converters is a type of circuit simulation that is used to determine how a DC-DC converter responds to changes in the load current.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Load-step-circuit-and-diagram-1024x336.png\" alt=\"\" class=\"wp-image-7190\" width=\"768\" height=\"252\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Load-step-circuit-and-diagram-1024x336.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Load-step-circuit-and-diagram-300x99.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Load-step-circuit-and-diagram-768x252.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Load-step-circuit-and-diagram-1200x394.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_Load-step-circuit-and-diagram.png 1233w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption><br>Load Step Analysis <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Comparison of simulation and measurement results<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The simulation results show good agreement with the voltage measurements in the TS300012 datasheet. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Semtech-comparison-of-simulation-and-measurement-results.png\" alt=\"\" class=\"wp-image-7193\" width=\"453\" height=\"349\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Semtech-comparison-of-simulation-and-measurement-results.png 604w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Semtech-comparison-of-simulation-and-measurement-results-300x231.png 300w\" sizes=\"(max-width: 453px) 85vw, 453px\" \/><figcaption>Comparison of simulation and measurement results<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">AC Analysis<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">AC analysis is a powerful tool for designing and optimizing DC-DC converters. It provides the frequency response of the converter, which can be used to analyze its stability and performance under different conditions.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_AC-Bode-diagram-1-1024x340.png\" alt=\"\" class=\"wp-image-7210\" width=\"768\" height=\"255\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_AC-Bode-diagram-1-1024x340.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_AC-Bode-diagram-1-300x100.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_AC-Bode-diagram-1-768x255.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_AC-Bode-diagram-1.png 1192w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> <br><em>The AC Bode diagram of the Loop Gain<\/em> <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Efficiency Analysis<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">TINA and TINACloud also allow fast and accurate calculation of efficiency as a function of load current. <\/p>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"533\" height=\"396\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_function-of-time-1.png\" alt=\"\" class=\"wp-image-7206\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_function-of-time-1.png 533w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_function-of-time-1-300x223.png 300w\" sizes=\"(max-width: 533px) 85vw, 533px\" \/><figcaption>Efficiency as a function of time<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"534\" height=\"396\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_load-current.png\" alt=\"\" class=\"wp-image-7207\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_load-current.png 534w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_load-current-300x222.png 300w\" sizes=\"(max-width: 534px) 85vw, 534px\" \/><figcaption>Efficiency as a function of load current (Iout).<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"> Content of the video: <\/p>\n\n\n\n<ul class=\"wp-block-list\"><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=0s\">00:00<\/a> Introduction <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=31s\">00:31<\/a> Startup Transient Simulation   <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=122s\">02:02<\/a> Redesigning the circuit <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=251s\">04:11<\/a> Steady State Analysis <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=345s\">05:45<\/a> Line Step Analysis <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=378s\">06:18<\/a> Load Step Analysis <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=423s\">07:03<\/a> AC Analysis <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=461s\">07:41<\/a> Efficiency Analysis <\/li><li> <a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;t=494s\">08:14<\/a> Conclusion <\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Click&nbsp;<a href=\"https:\/\/www.youtube.com\/watch?v=LJX7cWa26FE&amp;list=PLScrHAmLYSQAcKY55w-gvpUvBNL4wgQCJ&amp;index=1\">here&nbsp;<\/a>to watch our video.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can learn more about TINACloud here:&nbsp;<a href=\"https:\/\/www.tinacloud.com\/\">www.tinacloud.com\ufeff<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can learn more about TINA here:<a href=\"https:\/\/www.tina.com\/\">&nbsp;www.tina.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud. Startup Transient Simulation The startup transient of a DC-DC converter is the period of time during which the converter is transitioning from its off state to its steady-state operating condition. Redesigning the circuit &hellip; <a href=\"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit&#8221;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":7169,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-7166","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit - The Circuit Design Blog<\/title>\n<meta name=\"description\" content=\"In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit - The Circuit Design Blog\" \/>\n<meta property=\"og:description\" content=\"In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/\" \/>\n<meta property=\"og:site_name\" content=\"The Circuit Design Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tinadesignsuite\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-29T16:47:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-20T04:29:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_blog-featured-image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"460\" \/>\n\t<meta property=\"og:image:height\" content=\"258\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Michael Koltai\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Michael Koltai\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/\"},\"author\":{\"name\":\"Michael Koltai\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/bb1f5800a993ca0eadc86a47d55cfae7\"},\"headline\":\"Online Design and Simulation of the Semtech TS30012 DC\\\/DC Switching Regulator Circuit\",\"datePublished\":\"2024-04-29T16:47:59+00:00\",\"dateModified\":\"2025-06-20T04:29:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/\"},\"wordCount\":412,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Online-design-of-the-Semtech_blog-featured-image.png\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/\",\"name\":\"Online Design and Simulation of the Semtech TS30012 DC\\\/DC Switching Regulator Circuit - The Circuit Design Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Online-design-of-the-Semtech_blog-featured-image.png\",\"datePublished\":\"2024-04-29T16:47:59+00:00\",\"dateModified\":\"2025-06-20T04:29:29+00:00\",\"description\":\"In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\\\/DC synchronous switching regulator evaluation circuit using TINACloud.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Online-design-of-the-Semtech_blog-featured-image.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Online-design-of-the-Semtech_blog-featured-image.png\",\"width\":460,\"height\":258,\"caption\":\"Online design of the Semtech_blog featured image\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Online Design and Simulation of the Semtech TS30012 DC\\\/DC Switching Regulator Circuit\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"name\":\"The Circuit Design Blog\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\",\"name\":\"The Circuit Design Blog\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"width\":240,\"height\":64,\"caption\":\"The Circuit Design Blog\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tinadesignsuite\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/bb1f5800a993ca0eadc86a47d55cfae7\",\"name\":\"Michael Koltai\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g\",\"caption\":\"Michael Koltai\"},\"sameAs\":[\"https:\\\/\\\/www.tina.com\"],\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/author\\\/michael\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit - The Circuit Design Blog","description":"In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/","og_locale":"en_US","og_type":"article","og_title":"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit - The Circuit Design Blog","og_description":"In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud.","og_url":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/","og_site_name":"The Circuit Design Blog","article_publisher":"https:\/\/www.facebook.com\/tinadesignsuite\/","article_published_time":"2024-04-29T16:47:59+00:00","article_modified_time":"2025-06-20T04:29:29+00:00","og_image":[{"width":460,"height":258,"url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_blog-featured-image.png","type":"image\/png"}],"author":"Michael Koltai","twitter_misc":{"Written by":"Michael Koltai","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#article","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/"},"author":{"name":"Michael Koltai","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/bb1f5800a993ca0eadc86a47d55cfae7"},"headline":"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit","datePublished":"2024-04-29T16:47:59+00:00","dateModified":"2025-06-20T04:29:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/"},"wordCount":412,"publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_blog-featured-image.png","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/","url":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/","name":"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit - The Circuit Design Blog","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#primaryimage"},"image":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_blog-featured-image.png","datePublished":"2024-04-29T16:47:59+00:00","dateModified":"2025-06-20T04:29:29+00:00","description":"In this video we demonstrate the online design and simulation of the Semtech TS30012 DC\/DC synchronous switching regulator evaluation circuit using TINACloud.","breadcrumb":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#primaryimage","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_blog-featured-image.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2024\/04\/Online-design-of-the-Semtech_blog-featured-image.png","width":460,"height":258,"caption":"Online design of the Semtech_blog featured image"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-semtech-ts30012-dc-dc-switching-regulator-circuit\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tina.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Online Design and Simulation of the Semtech TS30012 DC\/DC Switching Regulator Circuit"}]},{"@type":"WebSite","@id":"https:\/\/www.tina.com\/blog\/#website","url":"https:\/\/www.tina.com\/blog\/","name":"The Circuit Design Blog","description":"","publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tina.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tina.com\/blog\/#organization","name":"The Circuit Design Blog","url":"https:\/\/www.tina.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","width":240,"height":64,"caption":"The Circuit Design Blog"},"image":{"@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tinadesignsuite\/"]},{"@type":"Person","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/bb1f5800a993ca0eadc86a47d55cfae7","name":"Michael Koltai","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g","caption":"Michael Koltai"},"sameAs":["https:\/\/www.tina.com"],"url":"https:\/\/www.tina.com\/blog\/author\/michael\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/7166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/comments?post=7166"}],"version-history":[{"count":48,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/7166\/revisions"}],"predecessor-version":[{"id":7227,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/7166\/revisions\/7227"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media\/7169"}],"wp:attachment":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media?parent=7166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/categories?post=7166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/tags?post=7166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}