{"id":7904,"date":"2025-09-25T10:24:25","date_gmt":"2025-09-25T10:24:25","guid":{"rendered":"https:\/\/www.tina.com\/blog\/?p=7904"},"modified":"2025-09-26T07:59:59","modified_gmt":"2025-09-26T07:59:59","slug":"online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator","status":"publish","type":"post","link":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/","title":{"rendered":"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">We\u2019ve put together a new <a href=\"https:\/\/www.youtube.com\/watch?v=O_IygSEg2J0\">video tutorial <\/a>showing how to efficiently design and simulate power management circuits in TINACloud, using the Infineon&#8217;s TDA38826 DC-DC Point-of-Load (POL) regulator &nbsp;as the featured example. While this video focuses on TINACloud, you can also use the offline TINA program.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.infineon.com\/assets\/row\/public\/documents\/24\/49\/infineon-tda38826-datasheet-en.pdf\">The datasheet<\/a> of this device can be found on the <strong>Infineon website<\/strong> and was used to create the SPICE model for TINA and TINACloud by DesignSoft.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This model runs not only in TINA and TINACloud, but also in major SPICE programs including PSpice, SIMetrix, LTspice, and more.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The video covers the following topics:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Startup Transient Analysis<\/strong><\/li><li><strong>Steady State analysis<\/strong><\/li><li><strong>Line and Load Step Analysis<\/strong><\/li><li><strong>AC Analysis<\/strong><\/li><li><strong>Efficiency Analysis<\/strong><\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Startup Transient Analysis<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>startup transient<\/strong> is the time a DC-DC converter\ntakes to go from an off state to a stable, steady-state condition.\nTraditionally, simulating this can be time-consuming. However, TINA and\nTINACloud use a built-in <strong>average model<\/strong> that significantly speeds up this\nprocess, taking only a few seconds.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For more detailed results, the software can perform a <strong>switching-mode\ntransient analysis<\/strong>, which is still fast thanks to its advanced multi-core\nsolvers. Additionally, TINA and TINACloud can quickly calculate ripple voltages\nby combining the average and switching models.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To begin, you&#8217;ll open the &#8220;TDA38826 DC-DC\nPoint-of-Load (POL) regulator integrated&#8221; circuit file from the TINA\nExamples folder.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Running a Simulation<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">To perform a fast transient analysis, click the <strong>&#8220;Transient Analysis Fast&#8221;<\/strong> link or select <strong>&#8220;Transient\u2026&#8221;<\/strong> from the Analysis menu. By default, the &#8220;Use switching model&#8221; checkbox is unchecked, ensuring the fast average model is used. After clicking <strong>&#8220;Run&#8221;<\/strong>, a diagram will show the startup transient&#8217;s time function, with an output voltage of 1V.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_1V-min-1024x765.png\" alt=\"TDA 38826_Startup Transient Fast analysis\" class=\"wp-image-7926\" width=\"512\" height=\"383\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_1V-min-1024x765.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_1V-min-300x224.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_1V-min-768x574.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_1V-min.png 1029w\" sizes=\"(max-width: 512px) 85vw, 512px\" \/><figcaption> <em>TDA 38826_Startup Transient Fast analysis<\/em> <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Redesigning the Circuit<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">TINA and TINACloud&#8217;s <strong>Design Tool<\/strong> can automatically\nadjust circuit parameters to meet a new output voltage target. For example,\nlet&#8217;s change the output from 1V to 3.3V.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Select <strong>&#8220;Re-design this circuit&#8221;<\/strong> from the Tools menu or double-click the text box on the circuit. In the dialog box, simply change Vout to <strong>3.3V<\/strong> and click <strong>&#8220;Run&#8221;<\/strong>. The Design Tool will automatically adjust the necessary components, highlighting them in red. After running the transient analysis again, you can use a cursor to confirm the new output voltage is approx. 3.3V.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_3.3V-min-1024x765.png\" alt=\"\" class=\"wp-image-7930\" width=\"512\" height=\"383\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_3.3V-min-1024x765.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_3.3V-min-300x224.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_3.3V-min-768x574.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_fast_diagram_3.3V-min.png 1029w\" sizes=\"(max-width: 512px) 85vw, 512px\" \/><figcaption><em>TDA 38826_ After redesigning the circuit: Startup Transient fast analysis Vout is approx. 3.3V <\/em><\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">For a more accurate simulation, you can run the <strong>switching\nmodel<\/strong> by clicking the <strong>&#8220;Transient Analysis Accurate&#8221;<\/strong> link\nor checking the &#8220;Use switching model&#8221; box in the Run Transient\nAnalysis dialog. The calculation may take a few minutes, and the Vout curve\nwill be very similar to the one from the average model. The key difference is\nthat the switching model will show the <strong>ripple<\/strong>, which the average model\ndoes not. You can zoom in on the diagram to see the ripple voltage waveform\nmore clearly.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_Accurate_diagram_3.3V-min.png\" alt=\"\" class=\"wp-image-7932\" width=\"590\" height=\"414\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_Accurate_diagram_3.3V-min.png 787w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_Accurate_diagram_3.3V-min-300x210.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Startup_Accurate_diagram_3.3V-min-768x539.png 768w\" sizes=\"(max-width: 590px) 85vw, 590px\" \/><figcaption><em>TDA 38826 After redesigning the circuit: Startup Transient Accurate&nbsp;analysis<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Steady-State and Ripple Voltage Analysis\ufeff<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Steady-state analysis<\/strong> examines a circuit&#8217;s behavior\nafter all transients have settled. This is crucial for quickly determining <strong>ripple\nvoltages<\/strong>. This method is fast because it doesn&#8217;t require storing initial\ninductor and capacitor values. Using the same circuit file, you can perform a\ntransient analysis to view the ripple voltages and currents.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Steady-State_Accurate-min.png\" alt=\"\" class=\"wp-image-7934\" width=\"477\" height=\"381\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Steady-State_Accurate-min.png 954w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Steady-State_Accurate-min-300x240.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Steady-State_Accurate-min-768x613.png 768w\" sizes=\"(max-width: 477px) 85vw, 477px\" \/><figcaption><em>TDA 38826<\/em> Steady State analysis diagram<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\ufeffLine and Load Step Analysis<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">TINA and TINACloud can quickly simulate how a DC-DC\nconverter responds to sudden changes in input voltage (<strong>line step<\/strong>) or\nload current (<strong>load step<\/strong>).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Line Step Analysis<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To see the circuit&#8217;s response to an input voltage change, click the <strong>&#8220;Line Step Analysis Fast&#8221;<\/strong> link. A diagram of the circuit&#8217;s response, including the full ripple voltage, will appear within seconds <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Fast_diagram-min.png\" alt=\"\" class=\"wp-image-7936\" width=\"478\" height=\"380\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Fast_diagram-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Fast_diagram-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Fast_diagram-min-768x611.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption> <em>TDA 38826&nbsp;Line&nbsp;Step&nbsp;Fast&nbsp;Analysis&nbsp;diagram<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Accurate_diagram-min.png\" alt=\"\" class=\"wp-image-7940\" width=\"478\" height=\"380\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Accurate_diagram-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Accurate_diagram-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Line-Step-Accurate_diagram-min-768x611.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption><em>TDA 38826&nbsp;Line&nbsp;Step&nbsp;Accurate&nbsp;Analysis&nbsp;diagram<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"> <strong>Load Step Analysis<\/strong> <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><\/strong>To see the circuit&#8217;s response to a load current change, click the <strong>&#8220;Load Step Analysis Fast&#8221;<\/strong> link. The diagram will appear almost instantly. You can also run a more accurate, switching-mode version of this analysis by checking the <strong>&#8220;Use switching model&#8221;<\/strong> box.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Fast_diagram-min.png\" alt=\"\" class=\"wp-image-7945\" width=\"478\" height=\"380\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Fast_diagram-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Fast_diagram-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Fast_diagram-min-768x611.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption> <em>TDA 38826&nbsp;Load&nbsp;Step&nbsp;Fast&nbsp;Analysis&nbsp;diagram<\/em> <\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Accurate_diagram-min.png\" alt=\"\" class=\"wp-image-7947\" width=\"478\" height=\"381\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Accurate_diagram-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Accurate_diagram-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Load-Step-Accurate_diagram-min-768x612.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption> <em>TDA 38826&nbsp;Load&nbsp;Step&nbsp;Accurate&nbsp;Analysis&nbsp;diagram<\/em> <\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>AC Analysis<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The built-in average models also allow\nfor fast and accurate <strong>AC analysis<\/strong>. By clicking the <strong>&#8220;AC Transfer\nCharacteristic&#8221;<\/strong> link or selecting <strong>&#8220;AC Analysis&#8221;<\/strong> from\nthe menu, you can display the AC Bode diagram of the loop gain.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_AC-Bode_diagram-min.png\" alt=\"\" class=\"wp-image-7949\" width=\"478\" height=\"381\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_AC-Bode_diagram-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_AC-Bode_diagram-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_AC-Bode_diagram-min-768x612.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption><em>TDA 38826<\/em> AC Bode diagram<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Efficiency Analysis\ufeff<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">TINA and TINACloud\ncan quickly calculate and plot <strong>efficiency<\/strong> as a function of time and load\ncurrent. Clicking the <strong>&#8220;Efficiency Analysis Fast&#8221;<\/strong> link will\ngenerate a diagram showing efficiency versus time. By switching to the <strong>TR XY\nPlot Tab<\/strong>, you can also view efficiency as a function of the output or load\ncurrent.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-a-function-of-time-min.png\" alt=\"\" class=\"wp-image-7952\" width=\"478\" height=\"381\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-a-function-of-time-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-a-function-of-time-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-a-function-of-time-min-768x612.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption><em>TDA 38826<\/em> <strong>Efficiency<\/strong> as a function of time diagram<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-plot-min.png\" alt=\"\" class=\"wp-image-7954\" width=\"478\" height=\"381\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-plot-min.png 955w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-plot-min-300x239.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/TDA38826_Efficiency-as-plot-min-768x612.png 768w\" sizes=\"(max-width: 478px) 85vw, 478px\" \/><figcaption><em>TDA 38826<\/em> Efficiency as a function of the output or load current diagram<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">This concludes the <a href=\"https:\/\/www.youtube.com\/watch?v=O_IygSEg2J0\">video tutorial<\/a> on analyzing the key characteristics of the <strong>TDA38826 DC-DC Point-of-Load (POL) regulator<\/strong> using TINACloud.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can learn more about TINACloud here:&nbsp;<a href=\"https:\/\/www.tinacloud.com\/\">www.tinacloud.com\ufeff<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can learn more about TINA here:<a href=\"https:\/\/www.tina.com\/\">&nbsp;www.tina.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Explore more content from our channel: <a href=\"https:\/\/www.youtube.com\/@TinaDesignSuite\">https:\/\/www.youtube.com\/@TinaDesignSuite<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>We\u2019ve put together a new video tutorial showing how to efficiently design and simulate power management circuits in TINACloud, using the Infineon&#8217;s TDA38826 DC-DC Point-of-Load (POL) regulator &nbsp;as the featured example. While this video focuses on TINACloud, you can also use the offline TINA program. The datasheet of this device can be found on the &hellip; <a href=\"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator&#8221;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":7962,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-7904","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator - The Circuit Design Blog<\/title>\n<meta name=\"description\" content=\"This tutorial shows you how to use TINACloud to quickly and accurately design and simulate a power management circuit using the TDA38826 DC-DC Point-of-Load (POL) regulator.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator - The Circuit Design Blog\" \/>\n<meta property=\"og:description\" content=\"This tutorial shows you how to use TINACloud to quickly and accurately design and simulate a power management circuit using the TDA38826 DC-DC Point-of-Load (POL) regulator.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/\" \/>\n<meta property=\"og:site_name\" content=\"The Circuit Design Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tinadesignsuite\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-09-25T10:24:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-26T07:59:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1277\" \/>\n\t<meta property=\"og:image:height\" content=\"722\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Michael Koltai\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Michael Koltai\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/\"},\"author\":{\"name\":\"Michael Koltai\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/bb1f5800a993ca0eadc86a47d55cfae7\"},\"headline\":\"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator\",\"datePublished\":\"2025-09-25T10:24:25+00:00\",\"dateModified\":\"2025-09-26T07:59:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/\"},\"wordCount\":887,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/\",\"name\":\"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator - The Circuit Design Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png\",\"datePublished\":\"2025-09-25T10:24:25+00:00\",\"dateModified\":\"2025-09-26T07:59:59+00:00\",\"description\":\"This tutorial shows you how to use TINACloud to quickly and accurately design and simulate a power management circuit using the TDA38826 DC-DC Point-of-Load (POL) regulator.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png\",\"width\":1277,\"height\":722},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"name\":\"The Circuit Design Blog\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\",\"name\":\"The Circuit Design Blog\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"width\":240,\"height\":64,\"caption\":\"The Circuit Design Blog\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tinadesignsuite\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/bb1f5800a993ca0eadc86a47d55cfae7\",\"name\":\"Michael Koltai\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g\",\"caption\":\"Michael Koltai\"},\"sameAs\":[\"https:\\\/\\\/www.tina.com\"],\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/author\\\/michael\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator - The Circuit Design Blog","description":"This tutorial shows you how to use TINACloud to quickly and accurately design and simulate a power management circuit using the TDA38826 DC-DC Point-of-Load (POL) regulator.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/","og_locale":"en_US","og_type":"article","og_title":"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator - The Circuit Design Blog","og_description":"This tutorial shows you how to use TINACloud to quickly and accurately design and simulate a power management circuit using the TDA38826 DC-DC Point-of-Load (POL) regulator.","og_url":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/","og_site_name":"The Circuit Design Blog","article_publisher":"https:\/\/www.facebook.com\/tinadesignsuite\/","article_published_time":"2025-09-25T10:24:25+00:00","article_modified_time":"2025-09-26T07:59:59+00:00","og_image":[{"width":1277,"height":722,"url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png","type":"image\/png"}],"author":"Michael Koltai","twitter_misc":{"Written by":"Michael Koltai","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#article","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/"},"author":{"name":"Michael Koltai","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/bb1f5800a993ca0eadc86a47d55cfae7"},"headline":"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator","datePublished":"2025-09-25T10:24:25+00:00","dateModified":"2025-09-26T07:59:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/"},"wordCount":887,"publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/","url":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/","name":"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator - The Circuit Design Blog","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#primaryimage"},"image":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png","datePublished":"2025-09-25T10:24:25+00:00","dateModified":"2025-09-26T07:59:59+00:00","description":"This tutorial shows you how to use TINACloud to quickly and accurately design and simulate a power management circuit using the TDA38826 DC-DC Point-of-Load (POL) regulator.","breadcrumb":{"@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#primaryimage","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2025\/09\/Online-design-and-simulation-of-the-TDA38826_YT-tumbnail.png","width":1277,"height":722},{"@type":"BreadcrumbList","@id":"https:\/\/www.tina.com\/blog\/online-design-and-simulation-of-the-tda38826-dc-dc-point-of-load-pol-regulator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tina.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Online Design and Simulation of the TDA38826 DC-DC Point-of-Load (POL) regulator"}]},{"@type":"WebSite","@id":"https:\/\/www.tina.com\/blog\/#website","url":"https:\/\/www.tina.com\/blog\/","name":"The Circuit Design Blog","description":"","publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tina.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tina.com\/blog\/#organization","name":"The Circuit Design Blog","url":"https:\/\/www.tina.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","width":240,"height":64,"caption":"The Circuit Design Blog"},"image":{"@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tinadesignsuite\/"]},{"@type":"Person","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/bb1f5800a993ca0eadc86a47d55cfae7","name":"Michael Koltai","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/55ee279c69da09aa4b6d88bb27161d315e44c8687f8b45bde393391d2302673c?s=96&d=blank&r=g","caption":"Michael Koltai"},"sameAs":["https:\/\/www.tina.com"],"url":"https:\/\/www.tina.com\/blog\/author\/michael\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/7904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/comments?post=7904"}],"version-history":[{"count":68,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/7904\/revisions"}],"predecessor-version":[{"id":7997,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/7904\/revisions\/7997"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media\/7962"}],"wp:attachment":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media?parent=7904"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/categories?post=7904"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/tags?post=7904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}