{"id":8921,"date":"2026-04-07T14:32:23","date_gmt":"2026-04-07T14:32:23","guid":{"rendered":"https:\/\/www.tina.com\/blog\/?p=8921"},"modified":"2026-04-15T12:58:07","modified_gmt":"2026-04-15T12:58:07","slug":"max20830-demo-using-tinacloud","status":"publish","type":"post","link":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/","title":{"rendered":"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The MAX20830 is a fully integrated, high-efficiency step-down (buck) DC-DC switching regulator with a PMBus interface. The associated models can be used and executed in both TINA and TINACloud simulation environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The simulation results\nhave been verified against real measurement data, ensuring reliable and\naccurate performance for design and analysis purposes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img decoding=\"async\" class=\"wp-image-1659\" style=\"width: 18px;\" src=\"https:\/\/www.tina.com\/English\/tina\/wp-content\/uploads\/2019\/04\/tinacloud-play.jpg\" alt=\"\"><a href=\"https:\/\/www.youtube.com\/watch?v=Zmsfs21-rLQ&amp;t=3s\">In this video tutorial<\/a>, we\u2019ll first run simulations in TINACloud software, then verify the results with physical measurements.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"> Simulation with TINACloud <\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Part 1: Basic Simulation with TINACloud<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">To begin, we will simulate the output voltage adjustment via hardware components.<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li><strong>Open the Model:<\/strong> Navigate to the <code>TINA Examples\\Analog Devices<\/code> folder and open <strong>MAX20830_VOUT.TSC<\/strong>.<\/li><li><strong>Hardware Adjustment:<\/strong> The MAX20830 uses a default 0.5V feedback reference voltage (VREF\u200b). The external resistor divider determines the output voltage (VOUT). <ul><li>With RFB1\u200b and RFB2\u200b both set to <strong>1k\u03a9<\/strong>, the output voltage is <strong>1V<\/strong>.<\/li><li>Run a <strong>Transient Analysis<\/strong> to observe the 1V output.<\/li><\/ul><\/li><li><strong>Modifying the Output:<\/strong> To reach a <strong>5V<\/strong> output, change the RFB1\u200b value to <strong>9.1k\u03a9<\/strong> and run the Transient Analysis again.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram1-and-circuit-1-1024x479.png\" alt=\"\" class=\"wp-image-8973\" width=\"768\" height=\"359\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram1-and-circuit-1-1024x479.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram1-and-circuit-1-300x140.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram1-and-circuit-1-768x359.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram1-and-circuit-1.png 1186w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> Max20830 circuit with an output of 1V <\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram2-and-circuit-1024x481.png\" alt=\"\" class=\"wp-image-8958\" width=\"768\" height=\"361\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram2-and-circuit-1024x481.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram2-and-circuit-300x141.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram2-and-circuit-768x361.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram2-and-circuit-1200x563.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Vout_diagram2-and-circuit.png 1278w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> Max20830 circuit with an output of 5V <\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To change the output\nvoltage value without replacing the resistors, the reference voltage can be\nprogrammed via the PMBus commands.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Part 2: Adjusting Output via PMBus<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">\nWhile resistors provide a fixed output, the MAX20830 also allows for dynamic voltage scaling via PMBus commands without changing physical components.\n\n<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> Open the <strong>MAX20830 PMBus TSC<\/strong> file located in the <code>TINA Examples\\Analog Devices<\/code> folder. <\/p>\n\n\n\n<h6 class=\"wp-block-heading\">Device Configuration<\/h6>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Config-file-1024x575.png\" alt=\"\" class=\"wp-image-8925\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Config-file-1024x575.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Config-file-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Config-file-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Config-file-1200x674.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Config-file.png 1278w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>MAX20830 Configuration file<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The default configuration is programmed using a configuration file. This allows you to set key electrical parameters before start-up, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Reference voltage<\/li><li>Overcurrent protection threshold<\/li><li>Switching frequency<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These settings correspond to the internal registers of the MAX20830 and can be modified via <strong>PMBus commands<\/strong> to reprogram the device. For a detailed list of commands, refer to the <a rel=\"noreferrer noopener\" target=\"_blank\" href=\"https:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/max20830.pdf\">MAX20830 Datasheet<\/a>.<\/p>\n\n\n\n<h6 class=\"wp-block-heading\">Running the Analysis<\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">The MAX20830 is configured to power up with an initial output voltage of <strong>1V<\/strong> (using a default <strong>0.5V<\/strong> reference). To observe the device behavior:<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Navigate to the <strong>Analysis<\/strong> menu.<\/li><li>Select <strong>Transient&#8230;<\/strong> and press the <strong>Run<\/strong> button.<\/li><li>In the simulation, the output voltage is first allowed to reach its initial value.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram1_New.png\" alt=\"\" class=\"wp-image-8965\" width=\"684\" height=\"506\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram1_New.png 912w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram1_New-300x222.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram1_New-768x568.png 768w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> MAX20830: Running Transient Analysis <\/figcaption><\/figure><\/div>\n\n\n\n<h6 class=\"wp-block-heading\">PMBus Communication Sequence<\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">During the simulation, you can observe the PMBus communication protocol:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Device Address:<\/strong> Transmitted first. The address is set to hexadecimal <strong>31h<\/strong> via a 200\u03a9 resistor on the PGM0 pin.<\/li><li><strong>Command:<\/strong> The <strong>VOUT<\/strong> command (<strong>21h<\/strong>) is sent next.<\/li><li><strong>Data:<\/strong> To update the reference voltage to <strong>0.8V<\/strong>, the data bytes are sent (Lower byte: <strong>9Ah<\/strong>, Higher byte: <strong>01h<\/strong>).<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram2_New.png\" alt=\"\" class=\"wp-image-8967\" width=\"684\" height=\"506\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram2_New.png 912w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram2_New-300x222.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_diagram2_New-768x568.png 768w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/figure><\/div>\n\n\n\n<h6 class=\"wp-block-heading\">MAX20830EVKIT Physical Measurements<\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">To verify the simulation, we used the <strong>MAX20830EVKIT Evaluation Board<\/strong> connected to a <strong>MAXPOWERTOOL002<\/strong> USB-to-SMBus Interface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Monitoring Setup:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Output Voltage:<\/strong> Monitored via the Maxim Digital PowerTool software.<\/li><li><strong>PMBus Communication:<\/strong> Captured and monitored using a logic analyzer.<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Measurement-1024x559.png\" alt=\"\" class=\"wp-image-8930\" width=\"768\" height=\"419\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Measurement-1024x559.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Measurement-300x164.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Measurement-768x419.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Measurement-1200x655.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Measurement.png 1280w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> MAX20830EVKIT Physical Measurements <\/figcaption><\/figure><\/div>\n\n\n\n<h6 class=\"wp-block-heading\">Verification Results<\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">Just as in the simulation, the hardware starts with a <strong>1V<\/strong> output. A PMBus VOUT command was sent via the laptop to change the reference voltage to <strong>0.8V<\/strong>, resulting in an output voltage of <strong>1.6V<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The results\u2014specifically the transition from <strong>0.5V to 0.8V<\/strong>\u2014showed perfect consistency between the <strong>Maxim PowerTool<\/strong> and the <strong>TINACloud simulation<\/strong>. The communication sequences were clearly visible and identical in both the physical software and the simulation environment.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Result-of-measurements_New-1024x394.png\" alt=\"\" class=\"wp-image-8968\" width=\"768\" height=\"296\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Result-of-measurements_New-1024x394.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Result-of-measurements_New-300x115.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Result-of-measurements_New-768x295.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Result-of-measurements_New-1200x462.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/03\/MAX20830-DEMO-with-TINACloud_Result-of-measurements_New.png 1271w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>  MAX20830EVKIT Result of Measurements <\/figcaption><\/figure><\/div>\n\n\n\n<h6 class=\"wp-block-heading\">Conclusion<\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">In conclusion, the MAX20830 DC\u2011DC converter can be accurately simulated in TINACloud. The PMBus communication circuit-including the output\u2011voltage\u2011change command and the device\u2019s corresponding behavior-has been verified through measurements taken with the MAX20830EVKIT evaluation board.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can learn more about TINACloud here:&nbsp;<a href=\"https:\/\/www.tinacloud.com\/\">www.tinacloud.com\ufeff<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Explore more content from our channel: <a href=\"https:\/\/www.youtube.com\/@TinaDesignSuite\">https:\/\/www.youtube.com\/@TinaDesignSuite<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The MAX20830 is a fully integrated, high-efficiency step-down (buck) DC-DC switching regulator with a PMBus interface. The associated models can be used and executed in both TINA and TINACloud simulation environments. The simulation results have been verified against real measurement data, ensuring reliable and accurate performance for design and analysis purposes. In this video tutorial, &hellip; <a href=\"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":9065,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-8921","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud - The Circuit Design Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud - The Circuit Design Blog\" \/>\n<meta property=\"og:description\" content=\"The MAX20830 is a fully integrated, high-efficiency step-down (buck) DC-DC switching regulator with a PMBus interface. The associated models can be used and executed in both TINA and TINACloud simulation environments. The simulation results have been verified against real measurement data, ensuring reliable and accurate performance for design and analysis purposes. In this video tutorial, &hellip; Continue reading &quot;Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud&quot;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/\" \/>\n<meta property=\"og:site_name\" content=\"The Circuit Design Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tinadesignsuite\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-07T14:32:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-15T12:58:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Administrator\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Administrator\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/\"},\"author\":{\"name\":\"Administrator\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/0c1fdecdd1fce00fb47fa8f36d8ed200\"},\"headline\":\"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud\",\"datePublished\":\"2026-04-07T14:32:23+00:00\",\"dateModified\":\"2026-04-15T12:58:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/\"},\"wordCount\":612,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/\",\"name\":\"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud - The Circuit Design Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png\",\"datePublished\":\"2026-04-07T14:32:23+00:00\",\"dateModified\":\"2026-04-15T12:58:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png\",\"width\":1280,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/max20830-demo-using-tinacloud\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"name\":\"The Circuit Design Blog\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\",\"name\":\"The Circuit Design Blog\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"width\":240,\"height\":64,\"caption\":\"The Circuit Design Blog\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tinadesignsuite\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/0c1fdecdd1fce00fb47fa8f36d8ed200\",\"name\":\"Administrator\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g\",\"caption\":\"Administrator\"},\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/author\\\/blogadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud - The Circuit Design Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/","og_locale":"en_US","og_type":"article","og_title":"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud - The Circuit Design Blog","og_description":"The MAX20830 is a fully integrated, high-efficiency step-down (buck) DC-DC switching regulator with a PMBus interface. The associated models can be used and executed in both TINA and TINACloud simulation environments. The simulation results have been verified against real measurement data, ensuring reliable and accurate performance for design and analysis purposes. In this video tutorial, &hellip; Continue reading \"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud\"","og_url":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/","og_site_name":"The Circuit Design Blog","article_publisher":"https:\/\/www.facebook.com\/tinadesignsuite\/","article_published_time":"2026-04-07T14:32:23+00:00","article_modified_time":"2026-04-15T12:58:07+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png","type":"image\/png"}],"author":"Administrator","twitter_misc":{"Written by":"Administrator","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#article","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/"},"author":{"name":"Administrator","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/0c1fdecdd1fce00fb47fa8f36d8ed200"},"headline":"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud","datePublished":"2026-04-07T14:32:23+00:00","dateModified":"2026-04-15T12:58:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/"},"wordCount":612,"publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/","url":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/","name":"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud - The Circuit Design Blog","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#primaryimage"},"image":{"@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png","datePublished":"2026-04-07T14:32:23+00:00","dateModified":"2026-04-15T12:58:07+00:00","breadcrumb":{"@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#primaryimage","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/MAX20830-DEMO-with-TINACloud_YTtumbnail_New.png","width":1280,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/www.tina.com\/blog\/max20830-demo-using-tinacloud\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tina.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Simulation of MAX20830 DC-DC switching regulator with a PMBus interface using TINACloud"}]},{"@type":"WebSite","@id":"https:\/\/www.tina.com\/blog\/#website","url":"https:\/\/www.tina.com\/blog\/","name":"The Circuit Design Blog","description":"","publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tina.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tina.com\/blog\/#organization","name":"The Circuit Design Blog","url":"https:\/\/www.tina.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","width":240,"height":64,"caption":"The Circuit Design Blog"},"image":{"@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tinadesignsuite\/"]},{"@type":"Person","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/0c1fdecdd1fce00fb47fa8f36d8ed200","name":"Administrator","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g","caption":"Administrator"},"url":"https:\/\/www.tina.com\/blog\/author\/blogadmin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/8921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/comments?post=8921"}],"version-history":[{"count":44,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/8921\/revisions"}],"predecessor-version":[{"id":9072,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/8921\/revisions\/9072"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media\/9065"}],"wp:attachment":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media?parent=8921"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/categories?post=8921"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/tags?post=8921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}