{"id":9117,"date":"2026-04-30T13:54:09","date_gmt":"2026-04-30T13:54:09","guid":{"rendered":"https:\/\/www.tina.com\/blog\/?p=9117"},"modified":"2026-05-08T11:48:03","modified_gmt":"2026-05-08T11:48:03","slug":"converting-and-running-basic-multisim-live-circuits-in-tinacloud","status":"publish","type":"post","link":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/","title":{"rendered":"Converting and running Analog Multisim Live circuits in TINACloud"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">With the announcement that the <strong>Multisim Live simulator will be shut down on September 15, 2026<\/strong>, many engineers, educators, and students are looking for a reliable online alternative to continue their work.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">TINACloud offers a seamless transition path, allowing you to import, run, and analyze circuits created in Multisim v14.2 and Multisim Live. In this guide, we will walk through the process of converting analog circuits and exploring the advanced analysis features\u2014like symbolic analysis\u2014that TINACloud brings to your projects.<br><br> <a href=\"https:\/\/www.youtube.com\/watch?v=ua4DdTa6_Rs\">Click here or on the image above to watch this blog presented as a video tutorial<\/a>. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\n\n1. Exporting Your Design from Multisim Live\n\n<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Before moving to TINACloud, you need to retrieve your files from the Multisim Live environment.<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Open your desired circuit (e.g., a &#8220;Voltage Divider&#8221;) in Multisim Live.<\/li><li>Verify the design by clicking the <strong>Run<\/strong> button.<\/li><li>Once verified, stop the simulation and navigate to the <strong>Menu<\/strong>.<\/li><li>Select <strong>Download<\/strong> to save the circuit file to your computer.<\/li><\/ol>\n\n\n\n<h5 class=\"wp-block-heading\">\n\n2. Importing to TINACloud\n\n<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">TINACloud is designed to be compatible with various Multisim formats, including <code>.ms14<\/code>, <code>.ms13<\/code>, and the Multisim Live format, <code>.msjs<\/code>.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Step 1:<\/strong> Log into TINACloud and select <strong>Upload<\/strong> from the menu.<\/li><li><strong>Step 2:<\/strong> Locate your downloaded <code>.msjs<\/code> file and select it.<\/li><li><strong>Step 3:<\/strong> The circuit will appear in the TINACloud workspace, maintaining the original layout and parameters.<\/li><\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Voltage divider Circuit Analysis in TINACloud<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Along with numerical\nanalysis, TINA and TINACloud feature advanced capabilities such as symbolic\nanalysis &#8211; a particularly powerful aid in teaching, as it brings to light the\ntheoretical relationships that give meaning to the numerical values. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\n\nTo see this in action, go to the <strong>Analysis<\/strong> menu, select <strong>Symbolic Analysis<\/strong>, and choose <strong>Symbolic DC Result<\/strong>. TINACloud will return the mathematical formula for the output voltage, providing clarity that a simple numerical value cannot.\n\n<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit_Transient-analysis-1024x574.png\" alt=\"\" class=\"wp-image-9139\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit_Transient-analysis-1024x574.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit_Transient-analysis-300x168.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit_Transient-analysis-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit_Transient-analysis-1200x673.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit_Transient-analysis.png 1277w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>Analyzing a Voltage divider circuit by using Symbolic analysis<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Analyzing a more complex circuit<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Of course, Symbolic\nAnalysis is not limited to simple circuits &#8211; it handles more complex ones just\nas well.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To see this, select <strong>Current\nSource<\/strong> from the Sources component toolbar, rotate it by 180 degrees, add it\nto the circuit, and connect it in parallel with R2. Then perform a numerical\nanalysis first and repeat the calculation using Symbolic Analysis. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To obtain the numerical\nresult, press the DC button.&nbsp;&nbsp; <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_DC-analysis-1024x576.png\" alt=\"\" class=\"wp-image-9142\" width=\"768\" height=\"432\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_DC-analysis-1024x576.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_DC-analysis-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_DC-analysis-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_DC-analysis-1200x675.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_DC-analysis.png 1278w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> <br><strong>Analyzing a more complex circuit<\/strong> <\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To obtain the symbolic\nresult, follow the same menu path as before: <strong>Analysis<\/strong> &gt; <strong>Symbolic\nAnalysis<\/strong> &gt; <strong>Symbolic DC Result<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_Symbolic-analysis-1024x576.png\" alt=\"\" class=\"wp-image-9144\" width=\"768\" height=\"432\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_Symbolic-analysis-1024x576.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_Symbolic-analysis-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_Symbolic-analysis-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_Symbolic-analysis-1200x675.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Voltage-divider-circuit-with-IS_Symbolic-analysis.png 1278w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>Symbolic Analysis result<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The program returns the analytical formula, which produces the same result as the numerical calculation.&nbsp;<strong> The formula clearly demonstrates the application of the superposition theorem, expressing the total response as the sum of the partial responses due to the current source and the voltage source acting independently.&nbsp; &nbsp;This is what makes symbolic analysis such a valuable teaching tool: it exposes the inner structure of the calculation, which is otherwise lost in a purely numerical answer.<\/strong>&nbsp; <\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Series RLC Circuit Analysis in TINACloud <\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">We have already opened the circuit in Multisim Live and downloaded the file to our computer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">After launching\nTINACloud, let&#8217;s upload the file using the standard upload procedure. The\nschematic will appear, maintaining the same layout and parameters as seen in <strong>Multisim\nLive<\/strong>.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Numerical Analysis: <\/strong><strong>Transient Analysis, AC Analysis <\/strong><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Transient Analysis<\/strong><strong><\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Numerical analysis allows\nus to observe the circuit&#8217;s behavior over time and frequency through\ndata-driven simulations. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let&#8217;s first run a <strong>Transient\nAnalysis<\/strong>. To generate curves, run transient analysis via the <strong>Analysis\nmenu<\/strong>\\<strong>Transient&#8230;<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The curves will appear in\na single, shared diagram. The coordinate system magnifies\nthe view between the minimum and maximum values. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Round the axis scales for\nbetter readability: Click an axis to open the scale settings. Select the Round axis scale checkbox, then click\nOK. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To view multiple curves\nsimultaneously, go to the <strong>View<\/strong> menu and select &#8220;<strong>Collect curves<\/strong>&#8220;.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Enhance your results by\nadding a <strong>legend<\/strong> or individual <strong>labels<\/strong> to identify each curve.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Legend_labels-diagram-1024x576.png\" alt=\"\" class=\"wp-image-9146\" width=\"768\" height=\"432\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Legend_labels-diagram-1024x576.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Legend_labels-diagram-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Legend_labels-diagram-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Legend_labels-diagram-1200x675.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Legend_labels-diagram.png 1278w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>Series RLC circuit: Running transient analysis and adding a legend and labels to the curves<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>AC Analysis<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Now, let&#8217;s run<strong> AC\nAnalysis<\/strong>. Navigate to the <strong>Analysis <\/strong>menu, select <strong>AC Analysis<\/strong>,\nthen click <strong>AC Transfer Characteristic.<\/strong><strong>..<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can select several\ndiagrams from the list. Select the Amplitude and Phase\n(Bode)diagrams. A two-panel Bode diagram will\nappear. As with the transient analysis, you can round the axis scales for\nclarity. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_AC-diagram-1024x576.png\" alt=\"\" class=\"wp-image-9150\" width=\"768\" height=\"432\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_AC-diagram-1024x576.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_AC-diagram-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_AC-diagram-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_AC-diagram-1200x675.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_AC-diagram.png 1279w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> Series RLC circuit: AC Bode diagram<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To perform other types of\nanalysis, return to the <strong>Analysis <\/strong>menu and select <strong>AC Analysis<\/strong> &gt;\n<strong>AC Transfer Characteristic&#8230; <\/strong>From there, you can choose Nyquist in the\nAnalysis window to generate the diagram. To improve the resolution of the plot,\nincrease the number of points (e.g., from 100 to 1000) and click Run. The\nNyquist diagram appears. Adjust the axis scales as needed.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Nyquist-diagram-1024x576.png\" alt=\"\" class=\"wp-image-9148\" width=\"768\" height=\"432\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Nyquist-diagram-1024x576.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Nyquist-diagram-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Nyquist-diagram-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Nyquist-diagram-1200x675.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Nyquist-diagram.png 1279w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> Series RLC circuit: Nyquist diagram <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Symbolic Analysis<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Beyond numerical data,\nTINACloud can perform symbolic analysis to generate mathematical formulas that\ndescribe your circuit&#8217;s behavior. Go to the <strong>Analysis<\/strong> menu, select <strong>Symbolic\nAnalysis<\/strong>, then choose <strong>Symbolic AC Transfer<\/strong>. The transfer function\nwill be displayed in its symbolic form, providing a direct analytical\nrepresentation of the circuit\u2019s performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Text Editor<\/strong>\nallows you to embed the symbolic formula within the circuit design.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Symbolic-diagram-1-1024x575.png\" alt=\"\" class=\"wp-image-9153\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Symbolic-diagram-1-1024x575.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Symbolic-diagram-1-300x168.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Symbolic-diagram-1-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Symbolic-diagram-1-1200x673.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_Series-circuit_Symbolic-diagram-1.png 1276w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> Series RLC circuit:  Embedding the symbolic formula within the circuit design <\/figcaption><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2nd Order Low Pass Filter Analysis<\/strong> <br><strong>in TINACloud<\/strong> <\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For our third example, we\nwill analyze a 2nd Order Low Pass Filter. Follow the standard procedure to <strong>download<\/strong>\nthe circuit file from <strong>Multisim Live<\/strong> and <strong>upload<\/strong> it to <strong>TINACloud<\/strong>.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Transient Analysis<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">First, let&#8217;s perform a\nTransient Analysis. Navigate to the Analysis menu and select Transient. In the\nsettings window, set the <strong>End Display<\/strong> time to <strong>100m<\/strong> and press Run. The\nresults will display the output (<strong>PR1<\/strong>) alongside the excitation signal (<strong>V1<\/strong>).\n<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Transient-diagram-1024x575.png\" alt=\"\" class=\"wp-image-9155\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Transient-diagram-1024x575.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Transient-diagram-300x168.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Transient-diagram-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Transient-diagram-1200x673.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Transient-diagram.png 1276w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>2nd Order Low Pass filter: Transient analysis diagram<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To view both signals in a\nsingle plot, go to <strong>View &gt; Collect Curves<\/strong>.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Using the Virtual Oscilloscope <\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">To observe the signals in\nreal-time, we can use the built-in Oscilloscope.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Close the current\ndiagram.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Go to the <strong>T&amp;M\n(Test and Measurement)<\/strong> menu and select <strong>Oscilloscope<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Click <strong>Run<\/strong> and\napply the following settings to clarify the signal: Set the <strong>Time\/Div <\/strong>to\n20ms and the <strong>Volts\/Div <\/strong>to 5V. Adjust the <strong>Time\/Div <\/strong>&nbsp;to 5ms for a more detailed view. To stabilize\nthe waveform, change the mode from <strong>Auto<\/strong> to <strong>Normal<\/strong>. Under the <strong>Source<\/strong>\ntab, select <strong>PR1<\/strong> as the trigger signal. You can now synchronize using\neither the <strong>positive<\/strong> or <strong>negative<\/strong> slope. Once finished, stop the\nsimulation and close the Oscilloscope window.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Oscilloscope-diagram-2-1024x575.png\" alt=\"\" class=\"wp-image-9160\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Oscilloscope-diagram-2-1024x575.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Oscilloscope-diagram-2-300x168.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Oscilloscope-diagram-2-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Oscilloscope-diagram-2-1200x673.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order-circuit_Oscilloscope-diagram-2.png 1276w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> 2nd Order Low Pass filter:  <strong>Using the Virtual Oscilloscope<\/strong> <\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>AC and Symbolic Analysis<\/strong><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>AC <\/strong> <strong>Analysis<\/strong> <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Now, let&#8217;s examine the\nfrequency response. Go to <strong>Analysis &gt; AC Analysis &gt; AC Transfer\nCharacteristic<\/strong>&#8230; Go to <strong>Analysis &gt; AC Analysis &gt; AC\nTransfer Characteristic<\/strong>&#8230; Both the <strong>Amplitude<\/strong> and <strong>Phase<\/strong> curves\nwill appear.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-with-the-circuit-1024x574.png\" alt=\"\" class=\"wp-image-9162\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-with-the-circuit-1024x574.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-with-the-circuit-300x168.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-with-the-circuit-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-with-the-circuit-1200x673.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-with-the-circuit.png 1278w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption>2nd Order Low Pass filter: AC Bode diagram<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Transitioning to Symbolic Analysis <\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Because a standard Op-Amp\nis a non-linear component, TINACloud must treat it as an Ideal Operational\nAmplifier to generate a mathematical formula<strong>.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let\u2019s first recalculate\nthe transfer characteristics numerically in a relevant voice frequency range.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Run AC Transfer\nCharacteristic again specifically for the voice frequency range (20Hz to 20kHz)\nwith 100 points.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Bode<\/strong> plots (Amplitude and Phase) are displayed. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-_Recalculate-1024x575.png\" alt=\"\" class=\"wp-image-9164\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-_Recalculate-1024x575.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-_Recalculate-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-_Recalculate-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-_Recalculate-1200x674.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_AC-Bode-diagram-_Recalculate.png 1276w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> 2nd Order Low Pass filter:  AC Bode diagram<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Now close the diagram and generate the formula. Go to <strong>Analysis &gt; Symbolic Analysis &gt; Symbolic AC Transfer<\/strong>. The <strong>Symbolic Transfer<\/strong> <strong>Function <\/strong>appears.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To add the resulting\nformula to your design, select the &#8220;<strong>Send to<\/strong>&#8221; tab and click\n&#8220;<strong>Text Editor<\/strong>&#8221; in the results window.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Check the text size, then\nclick <strong>OK<\/strong>. The symbolic transfer function is now embedded in your\nschematic.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_Symbolic-analysis-1024x575.png\" alt=\"\" class=\"wp-image-9166\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_Symbolic-analysis-1024x575.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_Symbolic-analysis-300x169.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_Symbolic-analysis-768x432.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_Symbolic-analysis-1200x674.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_Symbolic-analysis.png 1276w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption> 2nd Order Low Pass filter:  Symbolic Analysis<\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Comparing Ideal vs. Non-Linear Models <\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, we can verify\nthe accuracy of the ideal model by comparing it to the non-linear version. Open\nthe <strong>Interpreter<\/strong> and press <strong>Run<\/strong>. This draws the transfer function\nbased on the ideal model. Overlay this plot onto the existing Bode diagram to\ncompare it with the non-linear model.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Click<\/strong> the curve and select the &#8220;<strong>Copy Curve<\/strong>&#8220;icon to copy it to the clipboard. Next, switch to the AC\nBode Diagram tab, <strong>click <\/strong>on the plot area, and select the &#8220;<strong>Paste curve<\/strong>&#8221; icon. As you can see, the two curves match almost\nperfectly. The same is true for the phase characteristics, so let\u2019s perform\nthat comparison as well. Again, the agreement between the results is good;\nhowever, at higher frequencies the ideal op-amp shows deviations from the phase\nresponse of the more accurate nonlinear model.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_symbolic-and-Interpreter-diagram-1024x574.png\" alt=\"\" class=\"wp-image-9168\" width=\"768\" height=\"431\" srcset=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_symbolic-and-Interpreter-diagram-1024x574.png 1024w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_symbolic-and-Interpreter-diagram-300x168.png 300w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_symbolic-and-Interpreter-diagram-768x431.png 768w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_symbolic-and-Interpreter-diagram-1200x673.png 1200w, https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/Multisim_2nd-order_symbolic-and-Interpreter-diagram.png 1279w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">That brings us to the end\nof this tutorial on converting basic Multisim Live circuits and running them in\nTINACloud. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Be sure to check out our\nother videos on logic circuits and more advanced topics.&nbsp; <\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Conclusion<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Transitioning from Multisim Live doesn&#8217;t have to mean starting from scratch. TINACloud provides the tools to not only replicate your current work but to enhance it with symbolic formulas and integrated test equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As the 2026 deadline approaches, we encourage you to begin migrating your libraries to ensure your projects remain accessible and functional in a cloud-based environment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can learn more about TINACloud here:&nbsp;<a href=\"https:\/\/www.tinacloud.com\/\">www.tinacloud.com\ufeff<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Explore more content from our channel: <a href=\"https:\/\/www.youtube.com\/@TinaDesignSuite\">https:\/\/www.youtube.com\/@TinaDesignSuite<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>With the announcement that the Multisim Live simulator will be shut down on September 15, 2026, many engineers, educators, and students are looking for a reliable online alternative to continue their work. TINACloud offers a seamless transition path, allowing you to import, run, and analyze circuits created in Multisim v14.2 and Multisim Live. In this &hellip; <a href=\"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Converting and running Analog Multisim Live circuits in TINACloud&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":9138,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-9117","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Converting and running Analog Multisim Live circuits in TINACloud - The Circuit Design Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Converting and running Analog Multisim Live circuits in TINACloud - The Circuit Design Blog\" \/>\n<meta property=\"og:description\" content=\"With the announcement that the Multisim Live simulator will be shut down on September 15, 2026, many engineers, educators, and students are looking for a reliable online alternative to continue their work. TINACloud offers a seamless transition path, allowing you to import, run, and analyze circuits created in Multisim v14.2 and Multisim Live. In this &hellip; Continue reading &quot;Converting and running Analog Multisim Live circuits in TINACloud&quot;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/\" \/>\n<meta property=\"og:site_name\" content=\"The Circuit Design Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tinadesignsuite\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-30T13:54:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-08T11:48:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/TINAcLCloud-Multisim2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Administrator\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Administrator\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/\"},\"author\":{\"name\":\"Administrator\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/0c1fdecdd1fce00fb47fa8f36d8ed200\"},\"headline\":\"Converting and running Analog Multisim Live circuits in TINACloud\",\"datePublished\":\"2026-04-30T13:54:09+00:00\",\"dateModified\":\"2026-05-08T11:48:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/\"},\"wordCount\":1541,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/TINAcLCloud-Multisim2.png\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/\",\"name\":\"Converting and running Analog Multisim Live circuits in TINACloud - The Circuit Design Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/TINAcLCloud-Multisim2.png\",\"datePublished\":\"2026-04-30T13:54:09+00:00\",\"dateModified\":\"2026-05-08T11:48:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/TINAcLCloud-Multisim2.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/TINAcLCloud-Multisim2.png\",\"width\":1280,\"height\":720,\"caption\":\"Converting and running basic Multisim Live circuits in TINACloud tumbnail\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Converting and running Analog Multisim Live circuits in TINACloud\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"name\":\"The Circuit Design Blog\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#organization\",\"name\":\"The Circuit Design Blog\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"contentUrl\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/cropped-TINA_logo8.png\",\"width\":240,\"height\":64,\"caption\":\"The Circuit Design Blog\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tinadesignsuite\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/#\\\/schema\\\/person\\\/0c1fdecdd1fce00fb47fa8f36d8ed200\",\"name\":\"Administrator\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g\",\"caption\":\"Administrator\"},\"url\":\"https:\\\/\\\/www.tina.com\\\/blog\\\/author\\\/blogadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Converting and running Analog Multisim Live circuits in TINACloud - The Circuit Design Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/","og_locale":"en_US","og_type":"article","og_title":"Converting and running Analog Multisim Live circuits in TINACloud - The Circuit Design Blog","og_description":"With the announcement that the Multisim Live simulator will be shut down on September 15, 2026, many engineers, educators, and students are looking for a reliable online alternative to continue their work. TINACloud offers a seamless transition path, allowing you to import, run, and analyze circuits created in Multisim v14.2 and Multisim Live. In this &hellip; Continue reading \"Converting and running Analog Multisim Live circuits in TINACloud\"","og_url":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/","og_site_name":"The Circuit Design Blog","article_publisher":"https:\/\/www.facebook.com\/tinadesignsuite\/","article_published_time":"2026-04-30T13:54:09+00:00","article_modified_time":"2026-05-08T11:48:03+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/TINAcLCloud-Multisim2.png","type":"image\/png"}],"author":"Administrator","twitter_misc":{"Written by":"Administrator","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#article","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/"},"author":{"name":"Administrator","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/0c1fdecdd1fce00fb47fa8f36d8ed200"},"headline":"Converting and running Analog Multisim Live circuits in TINACloud","datePublished":"2026-04-30T13:54:09+00:00","dateModified":"2026-05-08T11:48:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/"},"wordCount":1541,"publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/TINAcLCloud-Multisim2.png","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/","url":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/","name":"Converting and running Analog Multisim Live circuits in TINACloud - The Circuit Design Blog","isPartOf":{"@id":"https:\/\/www.tina.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#primaryimage"},"image":{"@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/TINAcLCloud-Multisim2.png","datePublished":"2026-04-30T13:54:09+00:00","dateModified":"2026-05-08T11:48:03+00:00","breadcrumb":{"@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#primaryimage","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/TINAcLCloud-Multisim2.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2026\/04\/TINAcLCloud-Multisim2.png","width":1280,"height":720,"caption":"Converting and running basic Multisim Live circuits in TINACloud tumbnail"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tina.com\/blog\/converting-and-running-basic-multisim-live-circuits-in-tinacloud\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tina.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Converting and running Analog Multisim Live circuits in TINACloud"}]},{"@type":"WebSite","@id":"https:\/\/www.tina.com\/blog\/#website","url":"https:\/\/www.tina.com\/blog\/","name":"The Circuit Design Blog","description":"","publisher":{"@id":"https:\/\/www.tina.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tina.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tina.com\/blog\/#organization","name":"The Circuit Design Blog","url":"https:\/\/www.tina.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","contentUrl":"https:\/\/www.tina.com\/blog\/wp-content\/uploads\/2018\/07\/cropped-TINA_logo8.png","width":240,"height":64,"caption":"The Circuit Design Blog"},"image":{"@id":"https:\/\/www.tina.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tinadesignsuite\/"]},{"@type":"Person","@id":"https:\/\/www.tina.com\/blog\/#\/schema\/person\/0c1fdecdd1fce00fb47fa8f36d8ed200","name":"Administrator","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/18bbe29ef39b96f83a2e140ead8ffb89bdb119e09d2c6670e991485e757ab700?s=96&d=blank&r=g","caption":"Administrator"},"url":"https:\/\/www.tina.com\/blog\/author\/blogadmin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/9117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/comments?post=9117"}],"version-history":[{"count":47,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/9117\/revisions"}],"predecessor-version":[{"id":9189,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/posts\/9117\/revisions\/9189"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media\/9138"}],"wp:attachment":[{"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/media?parent=9117"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/categories?post=9117"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tina.com\/blog\/wp-json\/wp\/v2\/tags?post=9117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}