A new video tutorial is now available-showing you how to convert circuits from Altium Designer to TINACloud.
Converting a circuit schematic from Altium Designer to TINACloud allows you to leverage the best of both worlds: Altium’s powerful physical layout capabilities and TINA’s advanced simulation engine.
Key Benefits of Moving Circuits to TINACloud
1. Specialized and Advanced Simulation Capabilities:
More Ways to Analyze Your Circuit. After importing an Altium design into TINACloud, you can run more than 20 types of circuit analysis, including transient, AC frequency response, noise, Fourier, symbolic, harmonic balance, and S-parameter analysis.
TINACloud also supports microcontroller (MCU) simulation and models written in VHDL, Verilog, Verilog-A, SystemC, and other modeling languages.
Extensive Simulation Model Libraries. TINA and TINACloud include converter models from numerous manufacturers, including Texas Instruments, Infineon, Nisshinbo, Analog Devices, STMicroelectronics, Semtech, and others, as well as more than 1,400 microcontroller models.
Supported MCU families and platforms include PIC, AVR, 8051, ARM, ESP32, STM32, Arduino, XMC, and more. Our library of independently developed simulation models is also continuously expanding.
If you need a model for a specific device that is not yet available in TINA or TINACloud, please contact DesignSoft.
Virtual Instruments: TINACloud features interactive virtual test instruments (such as digital multimeters, real-time oscilloscopes, function generators, Logic Analyzer, Signal Analyzer) that make debugging intuitive.
2. Complete Cross-Platform Browser Accessibility:
No Installation Required:
TINACloud runs entirely inside any modern web browser across Windows, macOS, Linux, iOS, and Android.
Mobility:
You can view, edit, and run simulations on laptops, tablets, or even smartphones while away from your primary engineering desk.
Importing the Astable Multivibrator Schematic from Altium into TINACloud
Here is what our Astable Multivibrator circuit looks like in Altium.

Let’s test the circuit by running a Transient Simulation to check its initial behavior. Place two cursors on the waveform plot to read the exact values.
Next, package your design into a ZIP file (via Project > Project Packager…), and save it to your Downloads folder.
Now, open TINACloud and upload your ZIP file using the File > Upload> as Altium File command. The Astable Multivibrator schematic is now loaded and ready for testing in TINACloud.
Comparing the Simulation Results
Select Transient… from the Analysis menu to run the transient simulation. Now, place two cursors on the waveform to measure the results in TINACloud as well.
As shown on the screen, the period and waveforms in TINA and Altium are very similar, with minor differences depending on the simulator settings.
Importing the Active Band-pass filter Schematic from Altium into TINACloud
In this second example, we’re importing an active band-pass filter schematic from Altium Designer into TINACloud.
Here is the Active band-pass filter circuit in Altium Designer. Run the simulation.
Right-click in the top corner of the diagram (V(NetC2_2)), select Edit Wave, Choose Magnitude (dB) under Complex Functions, and click Create to display the response in decibels. Right-click on the dB label in the top-right corner of the diagram, select Cursor A, and position the cursor at the peak of the curve.
Next, select the project in the Projects panel and go to Project > Project Packager….Click Next to create the ZIP file in your folder, then click Finish.
Now, open TINACloud and go to File > Upload > as Altium File. Select BandpassFilter.zip and click Upload. The Active Band-pass filter schematic is now loaded and ready for testing in TINACloud. Go to Analysis > AC Analysis > AC Transfer Characteristic… Set the number of points to 500 and click Run.
Here is the resulting Bode diagram in TINACloud-and you can also switch to the AC Ampl 1 tab to view the gain curve directly.
As shown on screen, TINA and Altium give nearly identical resonant frequencies and gains at resonance, with only slight differences in the cursor readings.
Symbolic Analysis
Next, let’s explore Symbolic Analysis-a unique feature of TINA and TINACloud-along with plot visualisation. Go to the Analysis menu >Symbolic Analysis> Symbolic AC Transfer.
This substitution makes symbolic analysis possible, allowing TINACloud to generate the analytical transfer characteristic.
In the Symbolic Result window, click the Draw Diagram tab. Three plots will appear: the Amplitude plot, the Phase plot, and the combined Bode plot.
Comparing and Overlaying the Curves
To easily compare the two methods, first change the color of the analytical Amplitude Plot to Blue, and copy the curve to your clipboard. Then, switch over to the numerically calculated Bode Plottab, and paste the Blue curve directly into the Amplitude Plot. Repeat this exact same procedure for the Phase Plot.
When you look at the results, you can see that the numerical and analytical curves are in excellent agreement over the main operating range. This excellent agreement demonstrates exactly why ideal operational amplifiers are so widely used in active filter synthesis.
For more information visit us: www.tina.com, www.tinacloud.com
Visit our YouTube channel: www.youtube.com/@TinaDesignSuite